Measurement

Ask us for readings

Everyone in this industry claims cooling. Hardly anyone can prove it, because hardly anyone measures.

Every Stadthain has its own small weather station. It reports when the module needs water, and it publishes its readings – for every module individually and for anyone to read.

Simplified section through a module with its measuring points A module in side view with a flat, square canopy. Above the canopy sits a black sphere as the measuring point in the sun; directly below it, on the same vertical, an identical sphere as the measuring point in the shade. Next to it hangs a light, ventilated radiation shield holding the air temperature and humidity sensor. Sensors for soil moisture and the water reservoir level sit in the base. Reservoir Radiant temperature in the sun black sphere above the canopy Radiant temperature in the shade identical sphere, same vertical Air temperature and humidity in a ventilated radiation shield Soil moisture and tank level drives maintenance
Simplified section. Both spheres sit on the same vertical, one above and one below the canopy – the only difference between the two measuring points is the canopy. The air sensor hangs in a ventilated radiation shield; soil moisture and tank level are measured in the base. Electronics and power supply sit at the top of the mast, out of reach.

Quantities

Four values – one of them is spectacular

The other three are the reason you can believe it.

Quantities measured per module
QuantityPurpose
Air temperature The reference. Without it no other value means anything. It also gives the number of hot days at the site.
Humidity Shows the plants’ evaporation and flags when water sits in the radiation shield and the readings cannot be used.
Radiant temperature, two pointsthe spectacular one What a person actually feels. The comparison between above and below is what the module really tells you.
Soil moisture and tank level Operation. We see that watering is due before anyone else does – and from consumption, how much water the plant transpires.

The spectacular value needs the dullest one: a radiant temperature under the canopy says little on its own. Only together with the air temperature at the same minute does it become a statement – and that is exactly how we publish it.

Method

Fixed before measuring starts

This is the part nobody is usually interested in – until someone on the committee asks how you arrived at your figure. Then you have this.

  1. Both radiation sensors are identical and are co-located for 48 hours in shade and 48 hours in sun before installation. The deviation is documented; the raw values stay untouched.
  2. At the site both sit on the same vertical. Same spot, same height above the surroundings, same wind – the only difference is the canopy.
  3. The air sensor sits in a ventilated, light-coloured radiation shield. Without it, in the sun it would measure itself rather than the air – with an error larger than any effect one wants to show.
  4. Measurements are taken at a height of 2.7 m. The method statement says so, because both points need the same height and nothing should hang at head height.
  5. The evaluation rule is fixed before the first season and not changed afterwards.

Open data

We publish the figures of every module – viewable, shareable, usable

Every Stadthain gets its own page with its readings – not behind a login, not on request, but openly on the web.

Viewable

Daily curve of both measuring points, hot days at the site, water consumption over the season. Beside it the method statement, so everyone sees how it was measured.

Shareable

One link for the committee paper, the sustainability report or the press release. A figure anyone can check survives a conversation. One from our brochure does not.

Usable

The raw data is available as a download. Anyone who wants to recalculate may do so – even if they reach a different result than we do.

The module carries a small sign with a QR code. Whoever sits on the bench sees the current readings of exactly that spot.

The series becomes more meaningful every year, because summers can only be compared over several years – and a trend convinces a committee more than a single big number.

Data protection

What the sensors record

Temperature, humidity, soil moisture, tank level, position and battery state of the module. No images, no audio, no motion detection, no personal data.

The data protection concept and the data processing agreement come with the quotation – your data protection officer does not have to ask for them.